Comments on: So you bought a VSD compressor — Now what? /so-you-bought-a-vsd-compressor-now-what/ Tips, Trends, Resources, News and Information Wed, 22 Apr 2020 14:49:33 +0000 hourly 1 https://wordpress.org/?v=7.1.2 By: CA /so-you-bought-a-vsd-compressor-now-what/#comment-386667 Wed, 22 Apr 2020 14:49:33 +0000 /?p=7071#comment-386667 If vsd run full load, compressor will supply max flow, what happen if vsd run with rpm 50%, the flow will 50% of max capacity?

]]>
By: Danny Green /so-you-bought-a-vsd-compressor-now-what/#comment-386650 Tue, 21 Apr 2020 19:08:29 +0000 /?p=7071#comment-386650 You have an Ingersol-Rand VSD in the picture, do you know why their factory settings on their VSD units are at 45% minimal and 70% of full load capacity?

The IR salesman sells it as capable of 75% turn down but it comes set at 45% minimal. I have been told that if the minimal is lowered that the customer looses their warranty. Can you verify these things?

]]>